Find Jobs
Hire Freelancers

Water Design and Eletric Design for Campground -- 2

$250-750 USD

Completed
Posted over 6 years ago

$250-750 USD

Paid on delivery
I need the attached cad diagram of our campground development modified so that it includes waterlines and electric lines. Both sets will be buried. The current cad file has 3 diagrams. The diagram on the left is a subset of the one on the right. The left diagram is the first phase we are developing The right diagram shows all phases of development. You can ignore the diagram in the middle. The left diagram includes a road to the cottages and a place for parking near the cottages. We need this road copied to the diagram on the right. You will also notice the right diagram shows a 4 inch water line. This is wrong. We need a six inch water from the gate to near the cabins, and it need to terminate at a fire hydrant. It is also wrong for it to cross the septic line that is between the septic tank and its drain field (see cottage P7). The septic tank for P1 should be closer to the drain fields, which will make it easier to get water to the cabin without nearing a septic line. The waterline must be 25 feet from septic lines septic tanks and drain fields. We need a 3 inch line to branch off of the 6 inch line. The 3 inch line needs 7 branches one for each cottage. We need a valve on the 3 inch line just after it branches off the 6 inch line. Each of the 7 branches must terminate at a valve near each cabin. The water coming into the campgrounds enters from a 6 inch street main with 165 pounds per square inch of pressure. We also would like to bury the electric lines. We need high voltage lines starting from the gate and terminating at two transformers one near the cottages on the north side of the lake and one near the cottages on the south side of the lake. From the transformers we need two phase wires with neutral to each cottage (four from one transformer and three from the other). Can you correct the diagram on the right, adding the missing road, moving the septic tank, correcting the water line (fire hydrant, valves), and adding the electric lines and transformers. Can you provide this new diagram in a autocad file by itself, and also include a pdf file that is 36 inches wide by 48 inches long?
Project ID: 15516035

About the project

1 proposal
Remote project
Active 7 yrs ago

Looking to make some money?

Benefits of bidding on Freelancer

Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
Awarded to:
User Avatar
As discussed! Relevant Skills and Experience As discussed! Proposed Milestones $550 USD - Project cost for electrical and water plans of the campground
$550 USD in 5 days
5.0 (16 reviews)
6.5
6.5

About the client

Flag of UNITED STATES
Meadows Place, United States
5.0
1
Payment method verified
Member since Jun 11, 2016

Client Verification

Thanks! We’ve emailed you a link to claim your free credit.
Something went wrong while sending your email. Please try again.
Registered Users Total Jobs Posted
Freelancer ® is a registered Trademark of Freelancer Technology Pty Limited (ACN 142 189 759)
Copyright © 2024 Freelancer Technology Pty Limited (ACN 142 189 759)
Loading preview
Permission granted for Geolocation.
Your login session has expired and you have been logged out. Please log in again.